Rated Pressure: The rated operating pressure for these motors typically ranges from 280 - 350 bar (28 - 35 MPa). This pressure rating allows the motor to deliver the necessary torque for various applications such as in mobile machinery, industrial equipment, etc. For example, in heavy-duty machinery where high torque is required for tasks like lifting, pulling, or rotating heavy loads.
Maximum Pressure: The maximum pressure that the motor can withstand for short periods is usually higher than the rated pressure, often reaching up to 420 bar (42 MPa) or more. This provides a safety margin for handling sudden peak loads during operation.